Hanus Solution For Determination 1 Lt (Tespit için Hanus Çözelti) CAS: 7789-33-5, 64-19-7

Marka
Stok Kodu
109164.1000
Teklif İste
*
*
*
*
3 Günde Kargoda
Stok Sorunuz
Hanus Solution For Determination 1 Lt (Tespit için Hanus Çözelti) CAS: 7789-33-5, 64-19-7
 
Description
Catalogue Number 109164
Synonyms Iodine solution acc. to Hanus
Product Information
CAS number 7789-33-5, 64-19-7
HS Code 3822 00 00
Quality Level
Physicochemical Information
Density 1.06 g/cm3 (20 °C)
Flash point 40 °C
pH value <1 (H₂O, 20 °C)
Safety Information according to GHS
Hazard Pictogram(s) Hazard Pictogram(s)
Hazard Pictogram(s)
Hazard Statement(s) H226: Flammable liquid and vapour.
H314: Causes severe skin burns and eye damage.
Precautionary Statement(s) P210: Keep away from heat.
P280: Wear protective gloves/ protective clothing/ eye protection/ face protection.
P301 + P330 + P331: IF SWALLOWED: Rinse mouth. Do NOT induce vomiting.
P305 + P351 + P338: IF IN EYES: Rinse cautiously with water for several minutes. Remove contact lenses, if present and easy to do. Continue rinsing.
P308 + P310: IF exposed or concerned: immediately call a POISON CENTER or doctor/ physician.
Signal Word Danger
Storage class 3 Flammable Liquids
WGK WGK 1 slightly hazardous to water
Disposal 12
Inorganic acids and anhydrides thereof should first be diluted or hydrolyzed by stirring carefully into ice water and then neutralized (protective gloves, fume cupboard!) with sodium hydroxide solution (Cat. No. 105587). Before filling into container D, check the pH with pH universal indicator strips (Cat. No. 109535). Fuming sulfuric acid should be carefully stirred dropwise into 40 % sulfuric acid (Cat. No. 109286). Ensure that plenty of ice is available for cooling! When sufficiently cool, treat the highly concentrated sulfuric acid as described above. Analogous to this procedure, other anhydrides can be converted into their corresponding acids. Acid gases (e.g. hydrogen halide, chlorine, phosgene, sulfur dioxide) can be introduced into dilute sodium hydroxide solution and after neutralization disposed of in container D.
Safety Information
Hazard Symbols Hazard SymbolsCorrosive
Categories of danger flammable, corrosive
R Phrase R 10-35
Flammable.Causes severe burns.
S Phrase S 26-36/37/39-45
In case of contact with eyes, rinse immediately with plenty of water and seek medical advice.Wear suitable protective clothing, gloves and eye/face protection.In case of accident or if you feel unwell, seek medical advice immediately (show the label where possible).
Storage and Shipping Information
Storage Store at +15°C to +25°C.
Transport Information
Declaration (railroad and road) ADR, RID UN 2789 , 8 (3), II
Declaration (transport by air) IATA-DGR UN 2789 , 8 (3), II
Declaration (transport by sea) IMDG-Code UN 2789 , 8 (3), II, Segregation Group: 1 (Acids)
Specifications
Form liquid
Amount-of-substance concentration 0.0994 - 0.1006
Measurement uncertainty +/- 0.0004
Traceability NIST SRM
Accreditation: This volumetric solution is analyzed by our calibration laboratory D-K-15185-01-00 which is accredited according to
DIN EN ISO/IEC 17025 for analysis of amount-of-substance concentrations in volumetric solutions by DAkkS (Deutsche Akkreditierungsstelle - German National Accreditation Body). The accreditation certificate can be found at www.sigmaaldrich.com/ISO17025.
The concentration is determined by volumetric titration and refers to 20°C.
The amount-of-substance concentration of this volumetric solution is determined with standardized sodium thiosulfate solution (article number 1.09147). The sodium thiosulfate solution is standardized and traceable to a primary standard reference material (SRM) from the National Institute of Standards and Technology, Gaithersburg, USA (NIST SRM 136 potassium dichromate) by means of volumetric standard potassium iodate (article number 1.02404), certified reference material according to ISO 17034, analyzed by our accredited calibration laboratory of Merck KGaA, Darmstadt, Germany according to DIN EN ISO/IEC 17025. The uncertainty is expressed as expanded measurement uncertainty with a coverage factor k=2 covering a confidence level of 95%.
Note: The titer is a correction factor to correct for variations of the volumetric solution, the titration equipment, the temperature and other laboratory conditions. For correct titration results it is recommended to determine a titer with the laboratory specific equipment and under laboratory specific conditions directly after opening a new bottle and at regular time intervals.